Product Details:
|
| Usage: | Industrial Machinery, Measurement Instrument | Accuracy: | 0.5%FS |
|---|---|---|---|
| Power Consumption: | ≤6W | Working Environment: | 0~50℃ <85%RH |
| Communication: | RS485 | Working Voltage: | 100~240V AC/DC Or AC/DC 24V |
| ESD: | IEC/EN61000-4-2 | Safety Standard: | IEC61010-1 |
| Highlight: | Analog Output Temperature Controller RS485,DIN Rail Type Temperature Controller RS485 |
||
GTE series Guide Rail type PID Temperature Controller RS485 LCD display AC/DC 100~240V 0.5%FS SSR/RELAY/Analog output
1. Features and advantages of GTE digital temperature controller:
a). Module design, DIN-rail mounting.
b). Multi input signal and multi models for option.
c). Optional control output:RELAY/SSR/analog.
d). Communication and interconnection with host computer or touch screen via RS485.
e). Fuzzy adaptive PID algorithm and standard algorithm are optional.
f). LCD display, keypress operation, easy to control.
![]()
![]()
3. Technical specification:
Electrical parameter:
| Sample rate | 2 times per second |
| Relay capacity | AC 250V/1A lifespan of rated load>100,000 times(Resistive load) |
| Power supply | AC/DC 100~240V (85-265V) or AC/DC 24V |
| Power consumption | <6VA |
| Environment | Temperature of indoor:0~50℃ no condensation, Humidity:< 85%RH, altitude<2000m |
| Storage environment | -10~60℃, no condensation |
| SSR output | DC 24V pulse level, load<30mA |
| Current output | DC 4~20mA load<500Q , temperature drift 250PPM |
| Communication port | RS485 port, Modbus-RTU procotol, max input 30 uints |
| Insulation impedance | Input, output, power cabinet>20MQ |
| ESD | IEC/EN61000-4-2 Contact ±4KV/Air ±8KV perf.CriGTEria B |
| Pulse traip anti-interference | IEC/EN61000-4-4 ±2KV perf.CriGTEria B |
| Surge immunity | IEC/EN61000-4-5 ±2KV perf.CriGTEria B |
| Voltage drop & short interruption immunity | IEC/EN61000-4-29 0%~70% perf.CriGTEria B |
| Dielectric strength | Signal input & output & power 1500VAC 1min,below 60V Low voltage circuit between DC500V, 1min |
| Total weight | About 400g |
| Shell material | PA66-FR (Flame Grade UL94V-0) |
| Panel material | PVC film and PEM silicone key |
| Power-off data protection | 10years, times of writing:1 million times |
| Safety Standard | IEC61010-1 Overvoltage category U, pollution level 2, level n ( Enhanced insulation) |
Measuring signal specifications:
4. Dimention:
![]()
5. Connections:
![]()
6. Contact:
Sales: bassy shi
Cell phone: +86 13773069136
Email: bassy.shi@youjiazhineng.com
Contact Person: Ms. Julie
Tel: +86-180-2126-2273
Fax: 86-512-52843553