Send Message
Home ProductsKSD301 Thermal Switch

KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument

Certification
China Light Country(Changshu) Co.,Ltd certification
China Light Country(Changshu) Co.,Ltd certification
Customer Reviews
Thanks very much for your perfect quality and VIP service, we will keep contract and do more business with you!

—— Mark

We received your goods last thursday and we are very pleased with the quality of your product.

—— Igor Booklan

I'm Online Chat Now

KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument

KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument
KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument

Large Image :  KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument

Product Details:
Place of Origin: China
Brand Name: Light Country
Certification: UL, VDE, CQC
Model Number: T24
Payment & Shipping Terms:
Minimum Order Quantity: 1000pcs
Price: Depend on final design and demand quantity
Packaging Details: Tray and Carton
Delivery Time: 14~30days
Payment Terms: T/T in advance
Supply Ability: ≥10,000pcs per day.

KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument

Description
Product: KSD301 Thermal Switch Electrical Rating: 16A 250V, 15A 125V, 10A 250V
Temperature Range: 0℃~200℃ Tolerance: ±5℃
Lifetime: ≥100,000 Cycles Circuit Resistance: ≤50mΩ
Application: Physiotherapy Instrument

KSD301 Thermal Switch, Manual Reset, Used for thermal protection in Physiotherapy Instrument.

 

Some hospitals or physiotherapy instruments are using physiotherapy instruments, which are through heat transfer to relieve the pain of patients, help them to be recoved, then there is a relatively high requirement for the safety performance of the physiotherapy machine.

 

ksd301 thermal switch is the key component to the function of thermal protection, when the temperature of the physiotherapy machine is about to reach the non-safe level, the thermal switch will cut off the circuit, so that the temperature no longer rises. 

 

The physiotherapy instrument will restart manually after everything confirmed safe. 

 

1. About us:

Light Country was founded in 1985 in Taiwan. We dedicate on ksd301 thermal switch and rocker switch for around 40 years.

We’re with integration of design, production, sales and post-sales as well, to provide fast respond service and best price.

Our switches are widely used in household appliance, office equipment, beauty industry, medical devices and so on.

Our factory already got ISO9001, ISO14001, IATF16949 certificate.

Our switches have been recogized by CQC, UL/CUL, VDE, TUV, SEMKO, NEMKO, comply with ROHS/REACH regulations.

We promise reasonable price, stable quality, timely delivery and superior service.

 

2. Advantages of our ksd301 Thermal Switch:

1) High customzied design to fulfill customer's different installation demand.

2) Flexible production priority arrangement for hot orders. 

3) High precision, high sensitivity with 100% output inspection for excellent thermal protection performance.

4) Reasonable price and best considerate service.

 

3. Parameters and specification:

Factory name Light Country(Changshu)Co.,Ltd.
Product ksd301 Thermal Switch
Model T24
Type Manual Reset
Function  Thermal protection in physiotherapy instrument
Electrical Rating 16A/250V, 15A/125V, 10A/250V
Temperature range 0℃~200℃
Differential 8℃ or more, depend on customer's demand.
Cap Aluminum
Case PPS
Terminal Brass with tin plated, 0°.
Circuit Resistance ≤50mΩ
Insulation Resistance 100MΩ min. at DC 500V
Dielectric Strength AC 1450V/minute
Operating Life >100,000 cycles
Factory Certificate ISO9001, ISO14001, IATF16949

 

4. More ksd301 thermal switch styles/model options are as below. Please refer it and contact with us for best solution. 

KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument 0KSD301 Thermal Switch, Manual Reset, Used for Thermal Protection in Physiotherapy Instrument 1

5. FAQ.

Q1: How can we get a quote?
A: Please offer the specification details of the thermal switch, such as action temperature, automatic reset or manual reset,etc.

We will appreciate if any pictures or drawing are available for reference.

 

Q2: What about the lead time?
A: Less than 7 days for thermal switch sample production.

Around 10~20 days with long term forecast.

Around 20~30 days without forecast.

We will try best to support to shorten the lead time if any urgent order.

 

Q3: Delivery.

A: We prefer EXW term, but we can ask our forwarder source for transportation if customer need.

Contact Details
Light Country(Changshu) Co.,Ltd

Contact Person: Ms. Julie

Tel: +86-180-2126-2273

Fax: 86-512-52843553

Send your inquiry directly to us (0 / 3000)